Angelantoni Products
Adiprol® Lining Fume Hoods

Available in :
- TYPE: "C" frame base mounted fume hood with full height removable zinc coated steel panel with epoxy coating finish
- WIDTH : 1200 mm (4'), 1500 mm (5'), 1800 mm (6') or 2100 mm (7')  
- DEPTH : 810 mm (31 7/8") or 960 mm (37 13/16") 
- HEIGHT: 2300 mm (90 1/2") / 2500 mm (98  7/16") with sash totally opened
  
- TYPE: Base cabinets mounted fume hood (standard cabinets or acid/alkali storage cabinets)
- WIDTH : 1200 mm (4'), 1500 mm (5'), 1800 mm (6') or 2100 mm (7')  
- DEPTH : 810 mm (31 7/8") or 960 mm (37 13/16") 
- HEIGHT: 2300 mm (90 1/2")  / 2500 mm (98  7/16") with sash totally opened
  
- TYPE: Bench mounted fume hood 
- WIDTH : 1200 mm (4'), 1500 mm (5'), 1800 mm (6') or 2100 mm (7')  
- DEPTH : 810 mm (31 7/8")  
- HEIGHT: 1460 mm (57 1/2")  / 1660 mm (65  3/8") with sash totally opened

 Features: 
- Fire resistant Fume Hood (classified M 0 according to fire resistance Standard)
- Double wall type Fume Hood superstructure 
- Exterior shell of 1,5 mm (16 gauge) in epoxy powder coated finish removable to provide convenient access to service fixtures 
- Exterior front column removable for access to fixtures 
- Exhaust duct collar 250 mm ID  
- Instruction label attached to a corrosion resistant plate to the fume hood exterior  
- Interior lining (wall) including baffle of fire proof zinc coated steel (1,5 mm thk) with high chemical protection material ADIPROL® 
- Interior ADIPROL® liner is fire, heat, flame and chemical resistant 
- Two tube fluorescent light fixture pre wired to generate 500 lux minimum on work surface
- Dished surface epoxy resin worktop with cupsink (please contact us for other surface). Sealink gasket acts as a leak-resistant seam between hood and work surface to contain spills 
- 5 mm (3/16") thick tempered fixed framed safety glass sash (please contact us for other sash configuration). Safety sash counter balance system to retain the full weight of the counter weight in the event of cable breakage. Full length, recessed sash pull integral to the sash frame. Aerodynamic sash opening design. 
- Basic monitor (pre-wired) composed by : 
   * Light switch     
   * Exhaust fan switch        
or
- Airflow safety control monitor (pre-wired) composed by :
  * Light switch 
  * Exhaust fan switch
  * Constant airflow colored display of face velocity
  * Audible/visual alarm alerts the user to low face alert
  * Oversash opening visual alarm
  * Internal temperature controller with alarm and alert message (fire prevention)
  * "Silent reset" button
  * Port serie for calibrating airflow set-point and programming messages via the service module or PC
  * Global safety recommendation display for electrical failure, over opening sash, etc...with alert and/or recommendations digital messages
  * Minimum airflow switch for night-time reduction (reduced operation) only applicable to VAV Fume Hoods with motorized duct damper
  * Maximum airflow switch for emergency only applicable to VAV Fume Hoods with motorized duct damper
- Right and left columns are factory prepared for up to 10 service fixtures and up to 6 electrical receptacles   
- Standard service fixtures: 1 pre-plumbed remotely controlled water service fixture (please contact us to define additional service fixtures) 
- Standard electrical receptacles: 4 pre-wired electrical receptacles (please contact us to add electrical receptacles) 
- Conformed to EN 14175 